Glow Signage

LumiGLOW® and Nexit® glow signage can be customized as your requirment in order to enhance overall safety for both indoor and outdoor application such as glow evacuation exit signage, glow fire equipment signage, glow warning signage, glow information board and many more. There are also signage with standard symbols conforming TIS 2430 standard, EIT standard, and ISO 7010 standard. Customize signage requirement is also welcome.

 

Unique characteristic of LumiGLOW® glow signage

  • High luminance which meets test criteria of many global standards (JIS, DIN, ISO)
  • With pale yellow-white tone color under the light, the signage color is well matched in many area without vivid green color in color-theme controlling area while providing high glowing luminance in the dark
  • Able to absorb any kinds of light, including LED lamp, neon lamp, or sunlight.
  • Manufactured by using glow pigment which has patent in Japan.
  • The signage with class of High Glow or above are water-resistive signage. It can be used outdoor.
  • There are various size and many classes of glowing performance for your choice.
  • Flat and glossy surface allows easy cleaning by just wiping out even attached smut on surface. (Unlike ordinary PVC signage)
  • Surface closure material is PET which has better heat tolerance than PVC. This allows longer usage lifetime of signage than ordinary PVC glow signage.

 

Unique characteristic of Nexit® (by LumiGLOW) glow signage

  • High luminance which meets test criteria of global standards (DIN 67510 class D and above)
  • Provide high glowing luminance conforming global standard within limited budget.
  • Able to absorb any kinds of light, including LED lamp, neon lamp, or sunlight.
  • The signage is waterproof. It is good for both indoor and outdoor use.
  • The symbol and size can be customized as requested.
  • Flat and glossy surface allows easy cleaning by just wiping out even attached smut on surface. (Unlike ordinary PVC signage)
  • Surface closure material is PET which has better heat tolerance than PVC. This allows longer usage lifetime of signage than ordinary PVC glow signage.
  • Glow material can be printed on aluminum plate and create custom symbol as your need. (This type of signage provide ultimate glow level which meets DIN 67510 class E standard.)

 

LumiGLOW® product has weatherability test report to ensure product endurance and many more tests.

LumiGLOW® passed various global standards; for example

  • Water resistance test: Submerge a piece of LumiGLOW® sheet for 1 month. It is found that the glowing performance has no significant change.
  • Weatherability Test: Do cycle test according to JIS A 1415 standard by spray water for 18 minutes and then shine light with intensity of 180W/m2 by Xenon arc lamp for 102 minutes under ambient temperature of 63 Celcius centigrades and 50% humidity. There is no significant change in glowing performance after repeat this cycle for 1,000 hours (equivalent 5 years of outdoor usage).
  • Adhesive Test: Perform test by following methodology in JIS Z 0237 standard for both indoor and outdoor conditions.
  • Flamability Test: Perform test by following methodology in ASTM E 162-95 standard.
  • Smoke Intensity Test: Perform test by following methodology in ASTM E 662 standard.
  • Toxic Gas Generation Test: Perform toxic gas generation by following methodology in SMP-800C standard
  • Luminance Test: Perform test by following methodology in various global standards; JIS Z 9107, DIN 67510, ISO 17398
  • Luminance Test (Outdoor): Perform test by following methodology in JIS Z 9098 standard and ISO 22578 standard
  • Harzardous substances detection: Perform harzardous substances according to RoHS 2.0 standard which is widely applied in US, Europe, and worldwide in order to ensure that glow materials and products from LumiGLOW® and Nexit® are highly safe for human, animal-being and environment (Green product).
and etc.

 

Various dimensions for your choice with LumiGLOW® and Nexit® glow signage

LumiGLOW® has standard symbol for ready-to-buy glow signage and also can custom symbol as your request such as

  • Glow evacuation exit signage; size and symbol dimension conform with TIS 2430 standard and EIT standard.

Stadard glow evacuation exit signage
Glow evacuation signage, Glow emergency exit signage; Size 150 x 300 mm, 150 x 330 mm, 210 x 460 mm, 280 x 600 mm or any other sizes

  • Glow signage with fire equipment symbol; size and symbol conforms ISO 7010

Standard glow fire equipment signage
Glow signage with fire equipment symbol; Size 150 x 150 mm, 200 x 200 mm, 200 x 300 mm, 300 x 300 mm or any other sizes

  • Other glow signages

Other glow signages
Other glow signages
Other glow signages
Other glow signages
Other glow signages

 

Glow level of glow signage

LumiGLOW® glow signage has 4 classes of glowing performance as follow;

ป้ายเรืองแสงระดับต่างๆ
Remark: Glow signage with ultimate glow level (Shine Plate) is special product which is distributing in Japan, mainly used for outdoor application. So that the testing standard is JIS Z 9098 (Standard for outdoor use).

General usage instruction for appropriate class

  1. Standard Glow (DIN67510 class C): Good for ordinary building or building with sufficient light source (Not less than 50 lux)
  2. High Glow (DIN67510 class D): Good for middle risk building or building with low light environment
  3. Super Glow (DIN67510 class E): Good for high risk building or building with very low light environment
  4. Ultimate Glow (ISO 22578:2021): Good for area which requires ultra long glowing time such as outdoor usage / very low light building
Remark: Appropriate class is recommended by building height, number of stories, area, luminance level of the area, and etc.

 

Usage method and examples of glow signage

  1. Install on wall, wall trim, corridor, or direction guiding joint to indicate the closest exit.
  2. Install on door to indicate emergency exit door
  3. Indicate location of fire equipment, emergency tools or fire alarm.
  4. Giving disaster evacuation instruction or warning during ligh-off condition
  5. Indicate safe area for evacuation or assembly point
  6. Install on wall with height from ground to upper trim of signage less than 50cm in order to indicate emergency evacuation route (conform with EIT standard)

Usage example of glow signage
Usage example of glow signage
Usage example of glow signage
Usage example of glow signage
Usage example of glow signage

Photoluminescent (Glow-in-the-dark) product for your project

If you are looking for photoluminescent (Glow-in-the-dark) product,
please click below button to contact us directly.

Corporate customerRetail customer